{"id":5298,"date":"2024-07-18T15:58:30","date_gmt":"2024-07-18T23:58:30","guid":{"rendered":"https:\/\/jetstreamsoft.com\/portal\/?post_type=ht_kb&#038;p=5298"},"modified":"2025-02-13T15:44:32","modified_gmt":"2025-02-13T23:44:32","slug":"vcenter-alarm-drva-high-cpu-usage-duration-exceeded","status":"publish","type":"ht_kb","link":"https:\/\/jetstreamsoft.com\/portal\/jetstream-knowledge-base\/vcenter-alarm-drva-high-cpu-usage-duration-exceeded\/","title":{"rendered":"(Alarm) DRVA High CPU Usage Duration Exceeded"},"content":{"rendered":"\n<p class=\"is-style-info wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon\">This article applies to all JSDR software versions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Alarm<\/h2>\n\n\n\n<p class=\"\">This alarm is triggered when the CPU usage of a DRVA has exceeded an acceptable threshold. The threshold is set for 90% lasting 15 minutes or longer. Excessive CPU usage can impact the performance and efficiency of DR operations.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"29\" src=\"https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/msg-cpu-usage-1-1024x29.png\" alt=\"\" class=\"wp-image-5301\" srcset=\"https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/msg-cpu-usage-1-1024x29.png 1024w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/msg-cpu-usage-1-300x8.png 300w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/msg-cpu-usage-1-768x22.png 768w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/msg-cpu-usage-1-50x1.png 50w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/msg-cpu-usage-1-1536x43.png 1536w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/msg-cpu-usage-1-2048x58.png 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><em>Example: Alarm reported in vCenter.<\/em><\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"285\" src=\"https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/def-cpu-usage-1024x285.png\" alt=\"\" class=\"wp-image-5300\" srcset=\"https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/def-cpu-usage-1024x285.png 1024w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/def-cpu-usage-300x84.png 300w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/def-cpu-usage-768x214.png 768w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/def-cpu-usage-50x14.png 50w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/def-cpu-usage.png 1500w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><em>Example: Alarm definition in vCenter.<\/em><\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Possible Cause<\/h2>\n\n\n\n<p class=\"\">Excessive CPU usage can be caused by:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"\"><strong>Increased Workload:<\/strong> A sudden spike in the replication of data, recovery operations, or adding more domains\/VMs for protection can lead to higher CPU usage.<\/li>\n\n\n\n<li class=\"\"><strong>Resource Allocation:<\/strong> Insufficient CPU resources have been allocated to the DRVA.<\/li>\n\n\n\n<li class=\"\"><strong>Configuration<\/strong>: Improper configuration of the DRVA.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Resolution<\/h2>\n\n\n\n<p class=\"is-style-info wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon\">Collect the <a href=\"https:\/\/jetstreamsoft.com\/portal\/jetstream-knowledge-base\/collect-support-logs\/#msa-logs\">MSA support bundle<\/a> before proceeding with the following steps:<\/p>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li class=\"\">Verify the DRVA is adequately configured.\n<ul class=\"wp-block-list\">\n<li class=\"\">Ensure it is configured and meets the recommended specifications outlined in the <a href=\"https:\/\/jetstreamsoft.com\/portal\/online-docs\/jsdr-admin\/deploydrva.html\">Admin Guide<\/a>.<\/li>\n\n\n\n<li class=\"\">Adjust CPU and memory allocation, if necessary.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li class=\"\">Check processes running on the DRVA that may be consuming excessive CPU resources using the <kbd><strong>top <\/strong><\/kbd>command.<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"710\" height=\"419\" src=\"https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/top-command-cpu-usage-1.png\" alt=\"\" class=\"wp-image-5334\" srcset=\"https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/top-command-cpu-usage-1.png 710w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/top-command-cpu-usage-1-300x177.png 300w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/top-command-cpu-usage-1-50x30.png 50w\" sizes=\"(max-width: 710px) 100vw, 710px\" \/><figcaption class=\"wp-element-caption\"><em>Example: Results reported from the \u201ctop\u201d command.<\/em><\/figcaption><\/figure>\n\n\n\n<ol start=\"3\" class=\"wp-block-list\">\n<li class=\"\">Use the <a href=\"https:\/\/jetstreamsoft.com\/portal\/jetstream-knowledge-base\/capacity-planning-tool-cpt\/\">Capacity Planning Tool (CPT)<\/a> and make necessary adjustments based on the collected statistics of protected VMs.<\/li>\n\n\n\n<li class=\"\">Analyze the workload of protected VMs.\n<ul class=\"wp-block-list\">\n<li class=\"\">If the workload has increased significantly, consider distributing the protected VM load over multiple protected domains\/DRVAs.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li class=\"\">Validate the vCenter stats of the DRVA VM related to CPU.\n<ul class=\"wp-block-list\">\n<li class=\"\">Observe the timestamp of any spikes and correlate them to environmental changes.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"445\" height=\"438\" src=\"https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/graph-cpu-usage-2.png\" alt=\"\" class=\"wp-image-5333\" srcset=\"https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/graph-cpu-usage-2.png 445w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/graph-cpu-usage-2-300x295.png 300w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/07\/graph-cpu-usage-2-50x50.png 50w\" sizes=\"(max-width: 445px) 100vw, 445px\" \/><figcaption class=\"wp-element-caption\"><em>Example: CPU usage spike reported in vCenter.<\/em><\/figcaption><\/figure>\n\n\n\n<ol start=\"6\" class=\"wp-block-list\">\n<li class=\"\">Try rebooting the DRVA and observe any change in status.<\/li>\n\n\n\n<li class=\"\">The system will automatically hot-add additional CPU to the DRVA if CPU resources are available to be added.<\/li>\n<\/ol>\n\n\n\n<p class=\"is-style-alert wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon\"><a href=\"https:\/\/jetstreamsoft.com\/portal\/jetstream-knowledge-base\/contacting-jetstream-software\/\">Contact Jetstream Support<\/a>\u00a0with <a href=\"https:\/\/jetstreamsoft.com\/portal\/jetstream-knowledge-base\/collect-support-logs\/#msa-logs\">MSA logs<\/a> if you are unable to resolve the issue.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Alarm This alarm is triggered when the CPU usage of a DRVA has exceeded an acceptable threshold. The threshold is set for 90% lasting 15 minutes or longer. Excessive CPU usage can impact the performance and efficiency of DR operations. Possible Cause Excessive CPU usage can be caused by: Resolution<\/p>\n","protected":false},"author":1,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"nf_dc_page":"","footnotes":""},"ht-kb-category":[92],"ht-kb-tag":[249],"class_list":["post-5298","ht_kb","type-ht_kb","status-publish","format-standard","hentry","ht_kb_category-troubleshooting","ht_kb_tag-alarm-jetstream"],"_links":{"self":[{"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/ht-kb\/5298","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/comments?post=5298"}],"version-history":[{"count":4,"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/ht-kb\/5298\/revisions"}],"predecessor-version":[{"id":6630,"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/ht-kb\/5298\/revisions\/6630"}],"wp:attachment":[{"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/media?parent=5298"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/ht-kb-category?post=5298"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/ht-kb-tag?post=5298"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}