{"id":6061,"date":"2024-11-25T13:55:42","date_gmt":"2024-11-25T21:55:42","guid":{"rendered":"https:\/\/jetstreamsoft.com\/portal\/?post_type=ht_kb&#038;p=6061"},"modified":"2024-11-25T13:58:51","modified_gmt":"2024-11-25T21:58:51","slug":"vm-start-protection-fails-pbm-error-2","status":"publish","type":"ht_kb","link":"https:\/\/jetstreamsoft.com\/portal\/jetstream-knowledge-base\/vm-start-protection-fails-pbm-error-2\/","title":{"rendered":"VM Start Protection Fails (PBM Error)"},"content":{"rendered":"\n<p class=\"is-style-info wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon\">This article applies to all JSDR software versions.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Problem<\/h2>\n\n\n\n<p class=\"\">The <em>VM Start Protection<\/em> task fails while applying the storage policy. The task logs may indicate the following error:<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"537\" src=\"https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/11\/failed-to-apply-storage-policy-1.png\" alt=\"\" class=\"wp-image-6063\" style=\"width:604px;height:auto\" srcset=\"https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/11\/failed-to-apply-storage-policy-1.png 1000w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/11\/failed-to-apply-storage-policy-1-300x161.png 300w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/11\/failed-to-apply-storage-policy-1-768x412.png 768w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/11\/failed-to-apply-storage-policy-1-50x27.png 50w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><figcaption class=\"wp-element-caption\">VM Start Protection error message.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Cause<\/h2>\n\n\n\n<p class=\"\">If the failure error references <em>\u201cPBM error occurred during PreReconfigureCallback\u201d<\/em> it may be caused by underlying vCenter server issues.<\/p>\n\n\n\n<p class=\"is-style-alert wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon\">A potential cause of this issue may be a mismatch between the vCenter certificate and the host&#8217;s <em>&#8220;iofiltervp_castore.pem&#8221;<\/em> certificate located in <strong><kbd>\/etc\/vmware\/ssl<\/kbd><\/strong> under the ESXi Host.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Solution<\/h2>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li class=\"\">Ensure there are no underlying issues with vCenter server.<br><br><\/li>\n\n\n\n<li class=\"\">All JetStream DR appliances should be online and working as expected without any issues.<br><br><\/li>\n\n\n\n<li class=\"\">Confirm storage providers of the vCenter server are online.<br>(<strong>vCenter \u2192 Configure \u2192 Storage Providers<\/strong>)<br><br><\/li>\n\n\n\n<li class=\"\">If they are offline, try using the <em>Synchronize Storage Providers<\/em> or <em>Rescan <\/em>options.<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"373\" src=\"https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/11\/storage-providers-offline-1-20241125-215226-1024x373.png\" alt=\"\" class=\"wp-image-6065\" srcset=\"https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/11\/storage-providers-offline-1-20241125-215226-1024x373.png 1024w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/11\/storage-providers-offline-1-20241125-215226-300x109.png 300w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/11\/storage-providers-offline-1-20241125-215226-768x280.png 768w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/11\/storage-providers-offline-1-20241125-215226-50x18.png 50w, https:\/\/jetstreamsoft.com\/portal\/wp-content\/uploads\/2024\/11\/storage-providers-offline-1-20241125-215226.png 1500w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Storage providers are offline.<br><\/figcaption><\/figure>\n\n\n\n<p class=\"is-style-alert wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon\">All storage providers must be <em>online<\/em> before starting VM protection. <em>VM protection will fail if the IO Filter provider is offline.<\/em><\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ol start=\"5\" class=\"wp-block-list\">\n<li class=\"\">If the issue persists or cannot be resolved, reach out to Microsoft Support [AVS] or VMware support [On-Prem] for assistance with resolving storage provider issues and bringing them online.<br><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">Additional Information<\/h2>\n\n\n\n<p class=\"\">The following knowledge base articles from VMware can be consulted for information about setting the online status of storage providers.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"\"><a href=\"https:\/\/kb.vmware.com\/s\/article\/56619\">Remove VASA Provider from the vSphere Storage Monitoring Service (SMS) mob<\/a><\/li>\n\n\n\n<li class=\"\"><a href=\"https:\/\/kb.vmware.com\/s\/article\/88159\">Resolving IOFilter disconnected\/offline post upgrade to 7.0u2<\/a><\/li>\n\n\n\n<li class=\"\"><a href=\"https:\/\/kb.vmware.com\/s\/article\/76633\">Certain IOFIlter Providers are showing as offline<\/a><br><\/li>\n<\/ul>\n\n\n\n<p class=\"is-style-info wp-block-ht-blocks-messages wp-block-hb-message wp-block-hb-message--withicon\">Seek guidance from VMware support before attempting to implement the solutions described in these articles.<\/p>\n\n\n\n<p class=\"\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Problem The VM Start Protection task fails while applying the storage policy. The task logs may indicate the following error: Cause If the failure error references \u201cPBM error occurred during PreReconfigureCallback\u201d it may be caused by underlying vCenter server issues. Solution Additional Information The following knowledge base articles from VMware can be consulted for information [&hellip;]<\/p>\n","protected":false},"author":1,"comment_status":"open","ping_status":"closed","template":"","format":"standard","meta":{"nf_dc_page":"","footnotes":""},"ht-kb-category":[92],"ht-kb-tag":[214],"class_list":["post-6061","ht_kb","type-ht_kb","status-publish","format-standard","hentry","ht_kb_category-troubleshooting","ht_kb_tag-vmprotection"],"_links":{"self":[{"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/ht-kb\/6061","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/comments?post=6061"}],"version-history":[{"count":2,"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/ht-kb\/6061\/revisions"}],"predecessor-version":[{"id":6067,"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/ht-kb\/6061\/revisions\/6067"}],"wp:attachment":[{"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/media?parent=6061"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/ht-kb-category?post=6061"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/jetstreamsoft.com\/portal\/wp-json\/wp\/v2\/ht-kb-tag?post=6061"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}